uPVC Pipes Kasna Greater Noida

uPVC Pipes

Ankur Gold is amongst the largest manufacturers of high quality uPVC pipes and fittings.

ADVANTAGES OF ANKUR GOLD uPVC PIPES

  • Economical
  • Light weight
  • Easy handling
  • Non toxic – Non corrosive
  • Resistance to most chemicals
  • Low installation and maintenance Cost
  • Resistance to abrasion
  • Longer Life
  • Low thermal conductivity
  • Easy Laying and joining

DIMENSIONS OF UNPLASTICISED PVC PIPES (As per IS 4985:2000)

Wall Thickness
Nominal
Outside
Diameter
(Nominal Size)
Mean Outside
Diameter
Min Max
Class 1
0.25
Min Max
Class 2
0.40
Min Max
Class 3
0.60
Min Max
Class 4
0.80
Min Max
Class 5
1.00
Min Max
Class 6
1.25
Min Max
20 20.0 20.3         1.1 1.5 1.4 1.8
25 25.0 25.0       1.2 1.6 1.4 1.8 1.7 2.1
32 32.0 32.3       1.5 1.9 1.8 2.2 2.2 2.7
40 40.0 40.3     1.4 1.8 1.8 2.2 2.2 2.7 2.8 3.3
50 50.0 50.3     1.7 2.1 2.3 2.8 2.8 3.3 3.4 4.0
63 63.0 63.3   1.5 1.9 2.2 2.7 2.8 3.3 2.8 3.3 3.5 4.1
63 63.0 63.3   1.5 1.9 2.2 2.7 2.8 3.3 3.5 4.1 4.3 5.0
75 75.0 75.3   1.8 2.2 2.6 3.1 3.4 4.0 4.2 4.9 5.1 5.9
90 90.0 90.3 1.3 1.7 2.1 2.6 3.1 3.7 4.0 4.6 5.0 5.7 6.1 7.1
110 110.0 110.4 1.6 2.0 2.5 3.0 3.7 4.3 4.9 5.6 6.1 7.1 7.5 8.7
125 125.0 125.4 1.8 2.2 2.9 3.4 4.3 5.0 5.6 6.4 6.9 8.0 8.5 9.8
140 140.0 140.5 2.0 2.4 3.2 3.8 4.8 5.5 6.3 7.3 7.7 8.9 9.5 11.0
160 160.0 160.5 2.3 2.8 3.7 4.3 5.4 6.2 7.2 8.3 8.8 10.2 10.9 12.6
180 180.0 180.6 2.6 3.1 4.2 4.9 6.1 7.1 8.0 9.2 9.9 11.4 12.2 14.1
200 200.0 200.6 2.9 3.4 4.6 5.9 6.8 7.9 8.9 10.3 11.0 12.7 13.6 15.7
225 225.0 225.7 3.3 3.9 5.2 6.0 7.6 8.8 10.0 11.5 12.4 14.3 15.3 17.6
250 250.0 250.8 3.6 4.2 5.7 6.5 8.5 9.8 11.2 12.9 13.8 15.9 17.0 19.6
280 280.0 280.9 4.1 4.8 6.4 7.4 9.5 11.0 12.5 14.4 15.4 17.8 19.0 21.9
315 315.0 316.0 4.6 5.3 7.2 8.3 10.7 12.4 14.0 16.1 17.3 19.9 21.4 24.7

Notes:-

  • The table is based on metric series of pipe dimensions given in ISO 161/1 in respect of pipe dimension and ISO DIS 4422.
  • The wall thickness of pipes is based on a safe working stress of 8.6 MPa at 27°C and the working pressure gets reduced at sustained higher temperatures. Occasional rise in temperature as in summer season with concurrent corresponding reduction in temperature during nights has no deleterious effect on the life working pressure of the pipe considering the total life of pipes.
  • For class 1, 2 and 3 of all sizes, this requirement need not to be satisfied as the ratio of minimum wall thickness to nominal outside diameter does not exceed 0.035 in these cases

For Inquiry